Chapter 2 - Installation
The Interface Unit can be secured to a wooden wall using 4 screws or to
a concrete wall using 4 masonry anchors and suitable bolts.
If the unit is exposed to direct sunlight, the Sun Guard must be
installed to prevent overheating. Before the screws or bolts are firmly
secured, place the Sun Guard so that it is properly secured between the
unit and the wall.
Figure 2-6: Interface Unit with Sun Guard
Preparing the Power Cord
CAUTION
Electric Shock Hazard. The power plug should be connected only by a licensed
electrician.
The power cord should be environmentally protected with a ½ inch
conduit to the electrical junction box or breaker panel. If connecting to
a standard AC receptacle is required, attach a power plug that meets
local electrical regulations.
NOTE
The color codes of the power cable are as follows:
Black Phase ~
Grey/White Neutral 0
Yellow/Green Ground
BreezeACCESSS 900 System Manual
2-10