User's Manual
Table Of Contents
- System Description
- Introducing BreezeACCESS 900
- Cell Extender
- Subscriber Unit
- BreezeCONFIG( ACCESS
- Specifications
- Installing the Cell Extender
- Installing the SU-I Subscriber Unit
- Set-up and Initialization
- Aligning the Cell Extender’s SU-RA Antenna
- Aligning the SU-I Subscriber Unit’s Antenna
- Verifying Proper Operation
- Flexible Hopping Definition Mode
Installing the Cell Extender
Figure 2-2
Figure 2-2: 3" Pole Installation Using Special Brackets
illustrates the method of installing an SU-RA unit on a pole,
using the brackets and open-ended bolts.
NOTE
Be sure to insert the open ended bolts with the grooves pointing outward, since
these grooves enable you to use a screwdriver to fasten the bolts to the unit.
Connecting the Ground and IF Cables
The Ground terminal (marked ╤) and the IF cable connector (marked IF)
are located on the bottom panel of the SU-RA Radio Unit, as shown in
Figure 2-3
To connect the ground cable:
1. Connect one end of a grounding cable to the ground terminal and
tighten the ground screw firmly.
2. Connect the other end of the ground cable to a ground connection.
Manual Revision 1.0 - Preliminary
2-7