User's Manual
Table Of Contents
- System Description
- Introducing BreezeACCESS 900
- Cell Extender
- Subscriber Unit
- BreezeCONFIG( ACCESS
- Specifications
- Installing the Cell Extender
- Installing the SU-I Subscriber Unit
- Set-up and Initialization
- Aligning the Cell Extender’s SU-RA Antenna
- Aligning the SU-I Subscriber Unit’s Antenna
- Verifying Proper Operation
- Flexible Hopping Definition Mode
Specifications
Cell Extender
Mechanical
Table 1-11: Mechanical Specifications, Cell Extender
Unit Structure Dimensions (cm) Weight (kg/lb)
Interface Unit Metal box, wall mountable 28 x 23 x 11 5.9 / 13
SU-RA Metal box, 2”-3” pole
mountable
30.6 x 30.6 x 7. 2 2.5 / 5.5
900 MHz, 14 dBi,
60
o
x 16
o
, Adjustable
Azimuth
900 MHz, 10 dBi,
65
o
x 65
o
,
Flat Panel (H/V)
Plastic radome with
aluminum base plate,
1.5”-4” pole mountable
30.5 x 30.5 x1.5 1.5 / 3.3
900 MHz VPOL 9dBi
Omni Antenna
Fiberglass, 2.38” pole
mountable
244 x 3.4
(diameter)
1.8 / 4
Connectors
Table 1-12: Connectors, Cell Extender
Unit Connector Description
SU-IF TNC female jack, lightning protected
AU-ANT N-Type female jack, lightning protected
ETHERNET 10Base-T (RJ-45) in an sealed Physical Media
ENSR 1FB5 receptacle that mates with
ENSAM315 field attachable connector
Cell Extender
Power UL/CSA listed power cable through a Heyco-Flex
Straight Connector 8402 that fits ½” conduit. 15 ft.
cord, 3 wires, un-terminated. Requires fused 3
wire, single phase service.
ANT TNC jack, lightning protected SU-RA
Power 12 VDC from the Interface Unit via the IF cables
Antenna Port RF N-Type female jack
Manual Revision 1.0 - Preliminary
1-13