User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
4-2
BreezeACCESS 4.0 Commissioning
Manual Revision: 1.01
Verifying Connectivity
Verifying the Ethernet Connection
Once you have connected the unit to an Ethernet outlet, verify that the
Ethernet Integrity indicator (the yellow LED embedded in the Ethernet
connector) is on, indicating that the unit is connected to an Ethernet
segment. The Ethernet Activity indicator (the green embedded LED)
should blink whenever the unit receives or transmits traffic on the
Ethernet port.
Verifying Data Connectivity
(Subscriber Unit)
From a user’s PC or from a portable PC connected to the unit, ping the
Access Unit or try to connect to the Internet.
Verifying Telephone Connectivity
(Subscriber Units with Voice
support)
To verify correct operation of the telephone, a test telephone with the
default telephony parameters and a known IP address should be
connected to the system (the location of the test telephone is determined
by the system administrator).
Perform the following steps to verify telephone connectivity:
1. Use IP dialing to call the test telephone: dial * followed by the 12-digit
IP address of the test telephone. Verify connectivity. During the
conversation, verify that the other party has your IP address.
2. After terminating the call, the other party should use the test
telephone to call your IP address and verify that the telephone,
including the ringing circuits, functions properly.