BreezeACCESS 4.0 Commissioning
Manual Revision: 1.01
Accessing the Monitor Program
using Telnet
1. Connect a PC to the Ethernet port of the unit. See the table below to
determine the type of cable. Configure the PC’s IP parameters to
enable connectivity with the unit (the default IP Address is 10.0.0.1).
Run the Telnet application.
Table 1-2: Required Type of Ethernet Cable
2.
The Select Access Level menu appears. Select the access level
according to your authorized access rights. You will be requested to
enter your password. After entering the correct password press
Enter. Default passwords are listed in Table 1-1‚ page 1-3.
3. The Main Menu appears. Proceed as you would after connecting via
the MON port.
Operating the Monitor Program
1. Type an option number to open/activate the option. You may need to
press Enter in some cases.
2. Press Esc to exit a menu or option.
3. You can log-out and exit the monitor program from the Main Menu by
selecting X (exit). (To get to the Main Menu from anywhere in the
program, press the Esc key several times). You can also exit the
monitor program from anywhere in the program by simultaneously
pressing the Ctrl and X keys.
4. Reset the unit after making configuration changes for the new values
to take effect.
NOTE:
The Main Menu of the GU-BS (GPS and Alarms module) does not include the Basic
Configuration option.
Unit Type Connection to a
PC
Connection to a
hub
Subscriber Units Straight Crossed
Access Units Crossed Straight
GPS module Straight Crossed
NOTE:
The program will terminate automatically after a given period of inactivity specified by
the Log-Out Timer parameter.