User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
1-14
BreezeACCESS 4.0 Installation
Manual Revision: 1.01
Installing Modular Base
Station Equipment
BS-SH Slot Assignments
The base station chassis has ten slots.
Figure 1-7: BS-SH Chassis Slot Assignments
The two wide slots on both sides of the shelf accommodate the BS-PS or
BS-PS-AC power supply modules. The shelf is designed to support
power supply redundancy through the use of two power supply
modules. If a single power supply is used, it can be inserted in any of
the two available slots. When using two power supply modules, both
modules must be the same type (either both BS-PS or both BS-PS-AC).
The remaining eight slots can accommodate up to six active BS-AU
modules. Two extra slots are for an optional BS-GU GPS module and/or
for future use. Active BS-AU modules can be installed in any of the eight
slots. Unused slots should be covered by blank panels.
The BS-PS
The BS-PS provides power to all the modules installed in the BS-SH
chassis. The BS-PS front panel is shown in Figure 1-8‚ page 1-15.