User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
1-6
BreezeACCESS 4.0 Installation
Manual Revision: 1.01
440 MHz. The maximum allowed attenuation of the IF cable connecting
the outdoor unit to the indoor unit is 15 dB at 440 MHz, and the
maximum allowed DC resistance (the sum of the DC resistance of the
inner and outer conductors) is 1.5 ohm. This allows for cable length of
up to 30 m when using the standard RG 58 cable.
If longer cables are required, a cable with lower attenuation and/or DC
resistance should be used. Table 1-2‚ page 1-6 provides details
regarding some popular cables such as the RG 58 and RG 213. If the
spectral environment is polluted with noise in the 440 MHz band, it is
recommended to use a higher quality double-shielded cable such as the
LMR 200, LMR 240 and LMR 400 (manufactured by Times
Communications).
Indoor Equipment
The Indoor unit should be installed as close as possible to the point
where the IF cable enters the building. The location of the indoor unit
should also take into account the need to connect it to a power mains
outlet and to the CPE.
Table 1-2: IF Cables
Cable Type RG 58 RG 213 LMR 200 LMR 240 LMR 400
Maximum cable length (m) 30 100 45 65 150
NOTE:
The system complies with the ETS 300 385 standard and is protected against secondary
lightning strikes when its outdoor unit is properly grounded according to the applicable
country-specific industry standards for protection of structures against lightning. The
system complies with EN 61000-4-5, test level 3 (2kV).