User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
Specifications
3-5
BreezeACCESS 4.0 System Manual
GU-RA to BS-GU Communication
Environmental
Standards Compliance, General
Physical interface RS 422
Cable Type EIA RS 422 3 x 2 x 26AWG + 1 x 2 x 24 AWG FTP Shielded.
3 x 26 AWG twisted pairs for RS 422 communication and 1x 24 AWG pair
for power supply
Cable Impedance 100 +/- 15 ohm @ 1 MHz (RS 422 pairs)
DC Resistance RS 422 pairs: 145 ohm/km
Power supply pair: 94 ohm/km
Maximum Cable Length 120 meters
Operating
Temperature
Outdoor Units
-40
0
C to 55
0
C (GU-RA: -40
0
C to 85
0
C)
Indoor equipment
0
0
C to 40
0
C
Operating Humidity Outdoor Units 5%-95% non-condensing, weather protected
Indoor equipment 5%-95% non-condensing
Type Standard
EMC FCC part 15 EN 300 385
Safety UL 1950, EN 60950
Environmental ETS 300 019 part 2-3 class 3.2E for indoor units
ETS 300 019 part 2-4 class 4.1E for outdoor units
Radio FCC part 15.247, ETSI ETS 301 253