*TimeOuts
710.3.4.3.3
(*TelephonySignals 3)
Time Out parameters. If the
*TelephonyCountryStandard is set to
proprietary, the Time Out parameters may
be configured (read/write). For all other
country standards, the values are read-
only.
*MinimumFlashDetectTimeOut
710.3.4.3.3.1
(*TimeOuts 1)
The minimum on-hook time for identifying
it as a Hook Flash.
Integer
0-2,000 (milliseconds)
*MaximumFlashDetectTimeOut
710.3.4.3.3.2
(*TimeOuts 2)
The maximum on-hook time for identifying
it as a Hook Flash.
Integer
0-2,000 (milliseconds)
*DisconnectTimeOut
710.3.4.3.3.3
(*TimeOuts 3)
The minimum time for decision on an on-
hook (disconnect) condition.
Integer
0-2,000 (milliseconds)
*InterDigitTimeOut
710.3.4.3.3.4
(*TimeOuts 4)
Applicable only for pulse dialing. The
minimum time between two consecutive
pulses to be considered as separating
between two digits.
Integer
0-2,000 (milliseconds)
*CalledPartyReleaseTimeOut
710.3.4.3.3.5
(*TimeOuts 5)
The minimum time for an on-hook signal
on the called party side to be considered
as call disconnect.
Integer