User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
B-32
BreezeACCESS 4.0 System Manual
Manual Revision: 1.01
Alarms Parameters
MIB Parameter
(Location in Parenthesis)
Description Values/Range
*Alarms
710.3.3. 20
(brzAccessMib 20)
Alarms parameters
*GpsAlarms
710.3.3. 20.1
(*Alarms 1)
Applicable to GU only. GPS Alarms parameters.
*AlarmInTable
710.3.3. 20.1.1
(*GpsAlarms 1)
Applicable to GU only. Names and status of Alarms-In. Not
accessible.
*AlarmInTableEntry
710.3.3. 20.1.1.1
(*AlarmInTable 1)
Applicable to GU only. An Alarms In table entry. Not
accessible.
*AlarmInIdx
710.3.3. 20.1.1.1.1
(*AlarmInTableEntry 1)
Applicable to GU only. Read-only. Alarms In table index Integer
1-10
*AlarmInName
710.3.3. 20.1.1.1.2
(*AlarmInTableEntry 2)
Applicable to GU only. Alarm In name. Alarms 1 to 4 can
receive a name. The other are read-only.
DisplayString
(SIZE(0..31))
*AlarmInStatus
710.3.3. 20.1.1.1.3
(*AlarmInTableEntry 3)
Applicable to GU only. Read-only. The status (off or on) of
Alarm In entry.
Integer
off (0)
on (1)
na (255)
*AlarmOutTable
710.3.3. 20.1.2
(*GpsAlarms 2)
Applicable to GU only. Names, definition, control and status of
Alarms-Out. Not accessible.
*AlarmOutTableEntry
710.3.3. 20.1.2.1
(*AlarmOutTable 1)
Applicable to GU only. An Alarms Out table entry. Not
accessible.
*AlarmOutIdx
710.3.3. 20.1.2.1.1
(*AlarmOutTableEntry 1)
Applicable to GU only. Read-only. Alarms Out table index Integer
1-3
*AlarmOutName
710.3.3. 20.1.2.1.2
(*AlarmOutTableEntry 2)
Applicable to GU only. Alarm Out name. The other are read-
only.
DisplayString
(SIZE(0..31))
*AlarmOutDefinition
710.3.3. 20.1.2.1.3
(*AlarmOutTableEntry 3)
Applicable to GU only. Enter an Alarm-In number to activate
the Alarm-Out when this Alarm-In is ON. Enter A to activate
the Alarm-Out if ANY of the Alarms-In are ON. Enter N
for NONE (never activate the Alarm Out).
DisplayString
(SIZE(0..2))
1-10, A, N
*AlarmOutControl
710.3.3. 20.1.2.1.4
(*AlarmOutTableEntry 4)
Applicable to GU only. Alarm out control:
off (0) – turn alarm off.
on (1) – turn alarm on.
auto (2)-activate according to status of relevant alarm-in in
accordance with Alarm Out Definition.
Integer
off (0)
on (1)
auto (2)
na (255)
*AlarmOutStatus
710.3.3. 20.1.2.1.5
(*AlarmOutTableEntry 5)
Applicable to GU only. Read-only. The status (off or on) of
Alarm Out entry.
Integer
off (0)
on (1)
na (255)