User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
Appendix B
B-29
BreezeACCESS 4.0 System Manual
Unit Control Parameters
MIB Parameter
(Location in Parenthesis)
Description Values/Range
*UnitControl
710.3.3. 10
(brzAccessMib 10)
*ResetUnit
710.3.3. 10.1
(*UnitControl 1)
Applicable to all products. Resets
the unit and applies new parameter
values.
Integer
cancel (0)
resetSystemNow (1)
*SetDefaults
710.3.3. 10.2
(*UnitControl 2)
Applicable to all products. Sets unit
configuration to Defaults values
after the next reset.
completeFactory: All parameters
revert to Factory Defaults values
partialFactory: All parameters
revert to Factory Defaults values,
except the parameters required for
maintaining wireless connectivity.
completeOperator: All parameters
revert to Operator Defaults values
partialOperator: All parameters
revert to Operator Defaults values,
except the parameters required for
maintaining wireless connectivity.
Integer
cancel (0)
completeFactory (1)
partialFactory (2)
completeOperator (1)
partialOperator (2)
*UnitName
710.3.3. 10.3
(*UnitControl 3)
Applicable to all products. The unit
name.
DisplayString (SIZE(32))
A string of up to 32 printable ASCII
characters.
*FlashMemoryControl
710.3.3. 10.4
(*UnitControl 4)
Applicable to all products. Reset
And Boot From Shadow Version:
Activates the backup version.
Use Current Version After Reset :
The currently active version is
activated after reset.
Integer
Cancel (0)
resetAndBootFrom
ShadowVersion (1)
useCurrentVersion
AfterReset (2)
*ConsoleSpeed
710.3.3. 10.5
(*UnitControl 5)
Applicable to all products. The
communication speed of the
Monitor port.
Integer
s9600bps (1)
s19200bps (2)
s38400bps (3)
s57600bps (4)
s115200bps (5)
*MonitorLogoutTimer
710.3.3. 10.6
(*UnitControl 6)
Applicable to all products. Time-out
of management programs
(Monitor, Telnet).
Automatic exit if the program is
inactive for the defined time.
Integer
1-999 (minutes)
*UnitPasswords
710.3.3. 10.7
(*UnitControl 7)
*ReadOnlyPassword
710.3.3. 10.7.1
(*UnitPasswords 1)
Applicable to all products. The
User (read only) password.
DisplayString (SIZE(8)).
Up to 8 printable ASCII characters.
*InstallerPassword
710.3.3. 10.7.2
(*UnitPasswords 2)
Applicable to all products. The
Installer password.
DisplayString (SIZE(8)).
Up to 8 printable ASCII characters.
*AdminPassword
710.3.3. 10.7.3
(*UnitPasswords 3)
Applicable to all products. The
Administrator password. This is
also the SNMP Write Community
String.
DisplayString (SIZE(8)).
Up to 8 printable ASCII characters.
*EventLog
710.3.3. 10.10
(*UnitControl 10)
Applicable to all products. Event
Log parameters