User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
Appendix A
A-5
BreezeACCESS 4.0 System Manual
Loading an Upgrade to a Unit
with FLASH Type: S
Use the following table to determine which source file name to use,
according to the unit’s type.
X refers to the software version number, up to 5 decimal digits (e.g. for
software release 4.0.40, X=4040).
Use the SNMP write community <SnmpWriteCommunity>.fmr (default
write community is private) to define the destination filename. For
example: to load the upgrade file A3011S.SU to an SU whose IP address
is 206.25.63.55 use the following syntax:
>tftp –i 206.25.63.55 put A3011S.SU private.fmr
When loading is completed the following message is displayed: Loading
operation has been completed successfully.
The FLASH memory can store two software versions. One version is
called Current and the second version is called Shadow. The new
version is loaded into the Shadow (backup) FLASH memory.
To check that the new firmware was loaded properly, view the firmware
versions stored in the FLASH using the following procedure:
1. From the Main Menu, select 2 – Unit Control.
The Unit Control menu opens.
2. From the Unit Control menu, select 5 – Flash Memory Control.
The Flash Memory Control menu opens.
Unit Type File Name
AU AXS.BS
SU AXS.SU
SU with Voice AXS.SUV
GU AXS.GU
NOTE:
If you are upgrading a Subscriber Unit which is not associated with an AU, the unit will
reset every five minute (approximately) and the following message will be displayed:
FTL: file src\wpscan.c line 262 Too large number of scanning
attempts
The unit will reset and it will take more than a minute before you can re-establish the
connection to it. You should either have the SU associated with an AU before starting
the loading process or complete the loading process before the unit resets. Otherwise
you will have to try again until you complete the loading process.