3. From the Flash Memory Control menu, select S – Show Flash
Versions.
The display appears as follows:
Flash Versions
===========
Current Version: 3.0.39
Shadow Version: 4.0.40
Version After Reset:3.0.39
From the Flash Memory Control menu select the active software version,
using the following procedures:
To activate the backup (shadow) version:
1. From the Flash Memory Control menu select 1 - Reset and Boot from
Shadow Version.
The Reset and Boot from Shadow Version menu opens.
2. Select 1 – Reset Now and press ENTER.
3. The unit resets and the Shadow version is used as the newactive
version. Note that after the next reset, the Current version will be
activated again.
If the active version is the Shadow version and you wish to
continue using it after the next Reset, use the following procedure:
1. From the Flash Memory Control menu select 2 - Use Current Version
After Reset.
The Use Current Version After Reset menu opens.
2. Select 1 – Set As Default Now and press ENTER. This will actually
cause the names of the two versions to switch. The previous Shadow
version will now be called Current and vise versa. The following
message will be displayed:
UP (DOWN) Image FLASH will be operational (UP or DOWN
refers to the location in the flash memory).
The loading procedure is protected. An attempt to load an invalid
version (e.g. using <SnmpWriteCommunity>.fmr when trying to load a
new version to units with a FLASH Type: F) will be rejected.