Loading an Upgrade to a Unit
with FLASH Type: F
Use the following table to determine which source file name to use,
according to the unit’s type.
X, refers to the software version number, up to 5 decimal digits
(e.g. for software release 4.0.40, X=4040).
Use the SNMP write community <SnmpWriteCommunity>.dwn (the
default write community is private) to define the destination filename.
For example, to load the upgrade file A3011F.BS to an AU whose IP
address is 206.25.63.65 use the following syntax:
tftp –i 206.25.63.65 put A3011F.BS private.dwn
When version loading is completed the following message is displayed:
Loading operation has been completed successfully
The FLASH memory can store two software versions. One version is
called Current and the second version is called Shadow. The new
version is loaded into the Shadow (backup) FLASH memory.
To check that the new firmware was loaded properly, view the firmware
versions stored in the FLASH using the following procedure:
1. From the Main Menu, select 2 – Unit Control.
The Unit Control menu opens.
2. From the Unit Control menu, select 5 – Flash Memory Control.
The Flash Memory Control menu opens.
Unit Type Source File Name
AU AXF.BS
SU AXF.SU
SU with Voice AXF.SUV
GU AXF.GU
NOTE:
If you are upgrading a Subscriber Unit which is not associated with an AU, the unit will
reset every five minutes (approximately) and the following message will be displayed:
FTL: file src\wpscan.c line 262 Too large number of scanning
attempts
The unit will reset and it will take more than a minute before you can re-establish the
connection to it. You should either have the SU associated with an AU before starting the
loading process or complete the loading process before the unit resets. Otherwise you
will have to try again until you complete the loading process.