User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
A-2
BreezeACCESS 4.0 System Manual
Manual Revision: 1.01
6. To verify the connection, ping the unit’s IP address. Verify that ping
replies are being received.
The procedure to be used depends on the unit’s FLASH memory type.
Identify the FLASH memory type by using the monitor program,
connecting the PC to the unit either directly or via Telnet.
From the Main Menu, select 1 – Info Screens. From the Info Screen
menu select 1 – Show Unit Status. The last line of the Unit Status
display will indicate the FLASH type (type F or type S).
Use the TFTP utility, with the following syntax, to perform the upgrade:
tftp –i hostaddress put sourcefile [destinationfile]
Where -i is for binary mode, hostaddress is the IP address of the
unit to be upgraded, put defines that the PC (client) will send a file to
the hostaddress and destinationfile is the name of the file to be
loaded.