User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
Menus and Parameters
2-79
BreezeACCESS 4.0 System Manual
the chassis. Alarm In 5 (GPS Antenna Status) is generated internally in
the GU module, and it is turned on to indicate that proper PPS (pulse
per second) timing signals are received from the GPS antenna.
The GU module can also control 3 Alarm Out relay, where each relay
has a common contact, a normally open (NO) contact and a normally
closed (NC) contact.
The Alarm Parameters menu allows access to the following sub-menus:
! Alarms In Names.
! Alarms Out Names.
! Automatic Alarms Out Definition.
! Alarms Out Control.
! Show Alarm Parameters.
Alarms In Names
The Alarms In Names menu allows names for each of the four external
alarm indications that can be connected to the AL IN connector to be
defined. These names can reflect the specific environment in which the
module is being used (e.g. “Smoke Detector 1” or “Main Door”).
Each Alarms In Name can contain up to 31 printable ASCII characters
(case sensitive).
The default names are Alarm In 1 through Alarm In 4.
Alarms Out Names
The Alarms Out Names menu allows names for each of the three
external devices that can be connected to the AL OUT connector to be
defined. These names can reflect the specific environment in which the
module is being used (e.g. “Alarm Light 1”).
Each Alarms Out Name can contain up to 31 printable ASCII characters
(case sensitive).
The default names are Alarm Out 1 through Alarm Out 3.
Automatic Alarms Out Definition
The Automatic Alarms Out Definition menu allows you to define the
conditions under which each of the 3 Alarms Out are to be activated
(when operating in Automatic mode). The available options for each of
the three Alarms Out are:
! 1 – Activate if Alarm In 1 turns ON.
NOTES:
Over Temperature alarm indication is only supported by the AC power supply module.
In installations with a single power supply module, the GU module doesn’t function
(and therefore will not provide an alarm indication) upon total failure of the power
supply or upon failure of the 5 V module.