User's Manual

Table Of Contents
Menus and Parameters
2-73
BreezeACCESS 4.0 System Manual
" Cadence Off – The silence time (on) in the ringing-silence
sequence of the Ringer.
Valid values are 100 – 10,000 milliseconds.
" Duration - The maximum duration of activating the ringer.
Ringing will cease upon detecting off-hook condition.
Valid values are 0 – 10,000 seconds.
! Timeouts – Defines the following timeouts:
" Min. Flash Detect Timeout and Max. Flash Detect
Timeout – A short on-hook time that is between the values
of these two parameters will be considered as Hook Flash.
Valid values: 0 – 2,000 milliseconds
" Disconnect Timeout – The minimum time for decision on
an on-hook condition.
Valid values: 0 – 2,000 milliseconds
" Inter-Digit Timeout – Applicable only for pulse dialing. The
minimum time between two consecutive pulses to be
considered as separating between two digits.
Valid values: 0 – 2,000 milliseconds
" Called Party Release Timeout – The minimum time for an
on-hook signal on the called party side to be considered as
call disconnect.
Valid values: 0 – 10,000 seconds
The following tables provide details concerning the values of the
parameters of the various call progress tones and the ringer as well as
the Timeouts for the available country standards.