User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
2-72
BreezeACCESS 4.0 Operations and Administration
Manual Revision: 1.01
any reason the call was disconnected because of a problem in the
wireless link or incompatible capabilities) or if the user did not hang
up after exceeding the specified duration of the Dial, Ring Back,
Busy or Congestion Tones.
! High Level Error Tone – Defines the high level tone transmitted to
the earphone to better attract the attention of the user if he did not
hang up after exceeding the specified duration of the Error Tone.
The various tones are defined by specifying the following
parameters:
" Frequency 1 – One of two frequencies that can be used for
generating the applicable tone.
Valid values are 0-3000 (in Hz).
" Frequency 2 – The second of the two frequencies to be used
for generating the applicable tone.
Valid values are 0-3000 (in Hz).
" Level 1 – The level (in dBm) of Frequency 1.
Valid values are –32 to +3.
" Level 2 – The level (in dBm) of Frequency 2.
Valid values are –32 to +3.
" Cadence On – The ringing time (on) in the tones-silence
sequence of the tone.
Valid values are 100 – 10,000 milliseconds, 0 (0 means that
the tone is not used).
" Cadence Off – The silence time (off) in the tones-silence
sequence of the tone.
Valid values are 100 – 10,000 milliseconds, 0 (0 means no
silence – a continuous tone).
" Duration – The maximum duration of transmitting the tone
to the earphone. Tone generation will cease upon hang-up.
Valid values are 0 – 10,000 seconds.
! Ring Frequency - Defines the ring frequency parameters (that
define the ringing of the telephone set), if the selected Telephony
Country parameter is Proprietary. The following parameters can be
defined:
" Ringer Frequency – the frequency of activating the Ringer.
Valid values are: 17Hz, 20Hz, 25Hz, 50Hz.
" Cadence On – The ringing time (on) in the ringing-silence
sequence of the Ringer.
Valid values are 100 – 10,000 milliseconds.