User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
2-16
BreezeACCESS 4.0 Operations and Administration
Manual Revision: 1.01
The Rx, Tx and RTx per hop counters accumulate the number of
applicable frames since last reset. The counters can also be reset using
the Reset Counters option in either the Per Hop Statistics menu or in
the Traffic Counters menu.
The general rate (Frames per second) statistics is the average rate
during the last 64 hops.
The display is continuously updated. Press any key to exit.
Ping Test (AU, SU and GU)
The Ping Test menu includes the following options:
! Destination IP Address – Displays the IP address of the destination
unit for pinging. Allows entering an IP address (4 x 3 digit octets,
separated by dots).
The default IP address is 192.000.000.001.
! No. of Pings – Enter the number of ping attempts per session.
The allowed range is from 0 to 9999. Select 0 for continuous
pinging.
The default value is 1.
! Ping Frame Length – Enter the ping packet size.
The allowed range is from 60 to 1472 bytes.
The default value is 64 bytes.
! Ping Frame Timeout – Enter the ping frame timeout, which is the
amount of time (in ms) to wait between ping attempts.
The allowed range is from 200 to 60000 ms, in increments of 200
milliseconds (200, 400, 600,……60000).
The default value is 200 ms.
Num The number of the information row, assigned automatically and
sequentially by the program.
Freq The hopping frequency, according to the hopping sequence.
Rx The accumulated number of frames received at the specified
frequency since last reset.
Tx The accumulated number of frames transmitted successfully at
the specified frequency since last reset.
RTx The accumulated number of frames re-transmitted at the
specified frequency since last reset.
avrDBM
(avrRSSI)
The average RSSI (Received Signal Strength Indication) in dBm
or RSSI units (according to the RSSI Display Option) of all the
frames received at the specified frequency since the last reset. If
no frames have been received, the avrRSSI is NA (Not
Available).