User's Manual
Table Of Contents
- System Manual Book 1: System Description
- Introduction
- System Components
- Specifications
- System Specifications
- Radio and Modem
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication (SU-A/E, AU-E-NI, AU-E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- System Manual Book 2: Installation
- IF-Based Equipment
- Packing Lists
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- IF-Based Equipment
- System Manual Book 3: Commissioning
- System Manual Book 4: Operations and Administration
- Accessing the Monitor Program
- Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Configuration Download/Upload
- System Manual: Appendices
Menus and Parameters
2-7
BreezeACCESS 4.0 System Manual
community string. The procedure is the same as for
downloading/uploading configuration files, except that
the extension used for the file name is .cmr.
Examples (using the default SNMP Write community
string):
To upload the configuration file using DOS based TFTP
Client to an SU whose IP address is 206.25.63.65:
tftp 206.25.63.65 put Suconf private.cmr.
To download the configuration file from the same unit:
tftp 206.25.63.65 get private.cmr Suconf
" Set Partial Operator Defaults – Sets all parameters to the
values of the Operator Defaults configuration, except for
parameters that are necessary to maintain connectivity and
to enable management. These are the parameters included
in the Basic Configuration menu with the exception of the
Maximum Data Rate parameter. In addition, Passwords and
VLAN parameters are not changed.
" Save Current Configuration As Operator Defaults –
Defines the current configuration of the unit as the Operator
Defaults configuration. This option is only available with
Administrator access rights.
! Change Unit Name – Changes the name of the unit, which is also
the system name in MIB2. This name is also used as the prompt of
the monitor program menus.
Valid values: A string of up to 32 printable ASCII characters.
! Change Password – Changes the password(s). A user with Installer
access rights can change the passwords for Read Only and Installer
levels. A user with Administrator access rights can change the
passwords of all levels.
Valid values: A string of up to 8 printable ASCII characters.
Table 1-1‚ page 1-3 lists the default passwords for each of the access
levels.
NOTE:
Activating Set Complete Operator Defaults will result in loss of connectivity.
If the unit is managed remotely, you may lose the ability to communicate with it.
NOTE:
The Passwords are not changed upon setting the unit to default values (either Partial
or Complete).