Appendix B. Basic Parameters
BreezeACCESS Series 35 Base Station Equipment Installation Manual
•
Hopping Set
– Displays the selected hopping set. Each hopping standard has
3 hopping sets. The hopping set selected in this screen determines which
hopping sequences are available in the Hopping Sequence screen. Always
use the same hopping set per site (with different hopping sequences) to
minimize the possibility of collisions on the wireless media. The default
value is 1.
This parameter is set only in the AU. All the associated SUs learn its value
from the AU during the association process.
•
Hopping Sync
(BS-AU only) – Displays the current Hopping Sync status of
the unit and allows defining a new status. When several AUs that use the
same hopping set and different hopping sequences are co-located, their
operation should be synchronized in terms of hopping sequence initialization
and timing. One unit must be specified as a Master Unit and all other units
must be specified as Slave units. Available options are:
⇒
Idle
– No synchronization (stand-alone operation)
⇒
Master
– The AU that serves as a Master unit providing
synchronization signals to the Slave units
⇒
Slave
– An AU that operates as a Slave
The default is Idle.
Note:
Synchronization is not allowed by the radio regulations in certain
countries. In units using such standards, the Hopping Sync option is
not supported. See Table 5-1 for information on synchronization
support in the standards of various countries.