User's Manual
Specifications
BreezeACCESS Series 29 Base Station Equipment Installation Manual
5.4 Interfaces
Interface Outdoor Unit Indoor Equipment
RF (AU-E) N-Type jack lightning protected
IF TNC jack, lightning protected TNC jack, lightning protected
Ethernet 10BaseT (RJ-45) with two embedded LEDs
Monitor 3-pin low profile
Power 12 VDC via the IF cable 4-pin power connector (BS-PS)
DC plug for the AU-PS power supply (AU-NI)
5.5 Electrical
Outdoor Unit 12 VDC via the IF cable
Indoor Modular Shelf Equipment -48 VDC, 200 W for a fully equipped shelf
AU (Indoor + Outdoor): 25W
Indoor AU-NI Unit AU-NI: 12VDC/2.5A from AU-PS
AU-PS: 100 - 240 VAC, 47-63 Hz
5.6 Mechanical
Outdoor Unit AU-RE: 30cm x 12cm x 5cm, 2.2 kg
AU-RA: Depending on specific model
Indoor Modular Shelf Equipment BS-SH: 19",3U, depth 26cm, 6 kg. Fully loaded
Indoor AU-NI Unit AU-NI: 13cm x 8.6cm x 3cm, 0.5 kg
AU-PS: 10cm x 6.5cm x 3.5cm, 0.4 kg