User's Manual
Configuring System Parameters
BreezeACCESS Series 23 Base Station Equipment Installation Manual
3.2.4 Configuring Parameters Specific to BreezeACCESS MMDS
1.
Type
F
to access the
Flexible Hopping Definition
menu. Enter the required
Channels/frequencies. See Appendix C for a list of the standard MMDS
channels and frequencies.
2.
If more than one AU-BS is used, they should be synchronized for optimal
spectrum utilization. Type
6
to access the
Hopping Sync
selection screen and
enter the required option (Master or Slave). Type
7
to access the Hopping
Shift selection screen, and enter the required value.
Note:
Only one AU should be defined as Master. The other units should be
defined as Slaves. If only one AU is used, it should be defined as Idle.
3.3 Reset Unit
1.
From the
main menu
, type
2
to access the
Unit Control
menu.
2.
Type
1
to access the
Reset Unit
menu. Type
1
to reset the unit so that new
configuration settings are applied.
Note:
Should you make any mistakes during configuration or encounter any
problems associated with system configuration parameters, you may
configure the unit back to the factory defaults, as follows:
Type
2
in the Unit Control menu to access the Set Factory Defaults menu.
Type in
2
(Set Factory defaults-Full)
to load the default values. Reset the
unit for the factory defaults values to take effect.