User's Manual
Configuring System Parameters
Base Station Equipment Installation Manual 22 BreezeACCESS Series
3.2.3 Configuring Parameters Specific to BreezeACCESS XL
1.
Type
H
to access the Hopping Band selection screen. (if this screen is
available).Select the required option.
2.
If the selected Hopping Band option was one of the fixed bandwidths
(10MHz, 12MHz,…) or Single Channel, type
8
to access the Frequency
Offset selection screen. Enter the required value.
3.
If the selected Hopping Band option was Flexible Hopping Definition, or if
the
Hopping Band
option is not available in this model, type F to access the
Flexible Hopping Definition menu. Type
2
to access the Channel Spacing
selection screen (if available), and select the required value. Type
1
to
access the Define Sub-bands option and enter the required dub-
bands/frequencies. To verify that the required sub-bands/frequencies were
entered properly, type S to view the selected Sub-bands/frequencies.
If more than on AU-BS is used, they should be synchronized for optimal spectrum
utilization, as follows:
1.
Type
6
to access the Hopping Sync selection screen. Enter the required
selection (Master or Slave)
2.
Type
7
to access the Hopping Shift selection screen. Enter the required
value.
Note:
Only one AU should be defined as Master. The other units should be defined as
Slaves. If only one AU is used, it should be defined as Idle.