User's Manual
Configuring System Parameters
BreezeACCESS Series 19 Base Station Equipment Installation Manual
4.
Operate the monitor program as follows:
•
Type an option number to open/activate the option. You may need to
press the Enter key in some cases.
•
Press the Esc key to exit a menu or an option.
•
You can log-out and exit the monitor program from the
Main Menu
by simultaneously pressing the Ctrl and X keys. The session is
terminated automatically after a specific time of inactivity,
determined by the Log-out Timer. The default value for the Log-out
Timer is 5 minutes.
•
Reset the unit after making configuration changes for the new values
to take effect.
•
You can view the current parameters’ configuration by selecting 1 in
the Main Menu to Access the Info Screens menu, and then selecting
2 in the Info Screens menu to view the Basic Configuration
parameters.
3.2 Configuring Basic Parameters
The Basic parameters that must be properly configured in all Access Units during
the installation process include the ESSID, IP related parameters and frequency
related parameters. Proper configuration of these parameters is essential in order
to guarantee connectivity with the Subscriber Units, allowing remote configuration
of other parameters via either the wired or the wireless network. Configure the
following parameters according to the instructions supplied by the system
administrator:
•
Parameters common to all product lines:
⇒
ESSID
⇒
IP Parameters: DHCP Client and/or IP Address, Subnet Mask and
Default Gateway Address