User's Manual
Configuring System Parameters
BreezeACCESS Series 17 Base Station Equipment Installation Manual
3. CONFIGURING SYSTEM PARAMETERS
After completing the installation process as described in the preceding section,
proceed with configuration of the basic system parameters.
This section covers the configuration of basic installation parameters. Refer to the
Administration Manual for information related to other parameters.
Note:
Optionally, the product can be configured using Telnet over the Ethernet
port. See Appendix A of this manual for further information.
3.1 Getting Started with the Local Terminal
1.
Connect one end of the Monitor cable to the MON jack on the front panel of
the BS-AU module or the AU-NI unit. Connect the second end of the cable to
the COM port of the terminal. The COM port connector on the Monitor cable
is a 9 pin D-type plug.
2.
Run a terminal emulation program (e.g., ProComm or Windows
HyperTerminal) using the following setup:
Baud rate
9600
Data bits
8
Stop bits
1
Parity
None
Flow Control
Xon/Xoff
Connector
Available Com Port
3.
Press
Enter
. The
Select Access Level
menu appears. Select the access level
according to your authorized access level. You will be requested to enter
your password. After entering the correct password, press the Enter key.
The
main menu
appears as shown in Figure 3-1