User's Manual

Basic Installation
BreezeACCESS Series 9 Base Station Equipment Installation Manual
2.5.2 Connecting the Antenna Cable (AU-RE)
Connect an RF cable between the ANT connector (marked ANT) and the antenna.
In BreezeACCESS II and BreezeACCESS MMDS AU-RE units, the ANT
connector is located on the top panel of the unit. In BreezeACCESS XL units, the
ANT connector is located on the bottom panel.
2.5.3 Connecting the Ground and IF Cables
The Ground terminal (marked
)
and the IF cable connector (marked IF) are
located on the bottom panel of the Outdoor unit, shown in Figure 2-3 and in
Figure 2-4.
ETH
ALARM
IF
12V IN
Figure 2-3. BreezeACCESS II and BreezeACCESS MMDS AU-RA/AU-RE
Radio Unit Bottom Panel
ETH
IF
12V IN
ANT
ALARM
Figure 2-4. BreezeACCESS XL AU-RE Radio Unit Bottom Panel
Ground
Screw
Ground
Screw