User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
1-6
BreezeACCESS Version 4.3 Installation
Manual Revision: 3.0
IF Cable
The outdoor unit is connected to the indoor unit by means of an IF cable
carrying signaling, control signals and power. The IF frequency is
440 MHz. The maximum allowed attenuation of the IF cable connecting
the outdoor unit to the indoor unit is 15 dB at 440 MHz, and the
maximum allowed DC resistance (the sum of the DC resistance of the
inner and outer conductors) is 1.5 ohm. This allows for cable length of
up to 30 m when using the standard RG 58 cable.
If longer cables are required, a cable with lower attenuation and/or DC
resistance should be used. Table 1-2‚ page 1-6 provides details
regarding some popular cables such as the RG 58 and RG 213. If the
spectral environment is polluted with noise in the 440 MHz band, it is
recommended to use a higher quality double-shielded cable such as the
LMR 200, LMR 240 and LMR 400 (manufactured by Times
Communications).
Table 1-2: IF Cables
Indoor Equipment
The Indoor unit should be installed as close as possible to the point
where the IF cable enters the building. The location of the indoor unit
should also take into account the need to connect it to a power mains
outlet and to the CPE.
Cable Type RG 58 RG 213 LMR 200 LMR 240 LMR 400
Maximum cable length (m) 30 100 45 65 150
NOTE:
The system complies with the ETS 300 385 standard and is protected against secondary
lightning strikes when its outdoor unit is properly grounded according to the applicable
country-specific industry standards for protection of structures against lightning. The
system complies with EN 61000-4-5, test level 3 (2kV).