User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
C-48
BreezeACCESS Version 4.3 System Manual
Manual Revision: 3.0
*HighRetransmissionsRateOnTRAP (209) Alarm was set on:
Minor Severity Alarm:
a. The Retransmissions
Current Rate exceeds the
Retransmissions Minor
Alarm Threshold, and is
higher than the
Retransmissions Average
Rate by at least
Retransmissions Minor
Alarm Minimum Delta.
b. The Retransmissions
Current Rate has dropped
below the Retransmissions
Major Alarm Threshold but is
still higher than the
Retransmissions Minor
Alarm Threshold.
Major Severity Alarm: The
Retransmissions Current
Rate became higher than the
Retransmissions Major
Alarm Threshold.
*TrapAUAlarmsSeverity
*TrapTrafficStatisticsCurrentRate
*TrapTrafficStatisticsAverageRate
*HighRetransmissionsRateOffTRAP (210) Alarm was set off:
Minor Severity Alarm: The
Retransmissions Current
Rate dropped below the
Retransmissions Minor
Alarm Threshold.
Major Severity Alarm: The
Retransmissions Current
Rate dropped below the
Retransmissions Major
Alarm Threshold.
The alarm will be set off also
after activating Clear All
Alarms or after disabling the
AU Alarms Option.
*TrapTrafficStatisticsCurrentRate
*TrapTrafficStatisticsAverageRate
*HighDroppedFramesRateOnTRAP (211) Alarm was set on:
Minor Severity Alarm:
a. The Dropped Frames
Current Rate exceeds the
Dropped Frames Minor
Alarm Threshold, and is
higher than the Dropped
Frames Average Rate by at
least Dropped Frames Minor
Alarm Minimum Delta.
b. The Dropped Frames
Current Rate has dropped
below the Dropped Frames
Major Alarm Threshold but is
still higher than the Dropped
Frames Minor Alarm
Threshold.
Major Severity Alarm: The
Dropped Frames Current
Rate became higher than the
Dropped Frames Major
Alarm Threshold.
*TrapAUAlarmsSeverity
*TrapTrafficStatisticsCurrentRate
*TrapTrafficStatisticsAverageRate
*HighDroppedFramesRateOffTRAP (212) Alarm was set off:
Minor Severity Alarm: The
Dropped Frames Current
Rate dropped below the
Dropped Frames Minor
Alarm Threshold.
Major Severity Alarm: The
Dropped Frames Current
Rate dropped below the
Dropped Frames Major
Alarm Threshold.
The alarm will be set off also
after activating Clear All
Alarms or after disabling the
AU Alarms Option.
*TrapTrafficStatisticsCurrentRate
*TrapTrafficStatisticsAverageRate
Trap (Number) Description Variables