User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
Appendix C
C-39
BreezeACCESS Version 4.3 System Manual
brzPhoneMIB (applicable to SU
with voice only)
breezecom OBJECT IDENTIFIER =1.3.6.1.4.1.710
{(iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) breezecom(710)}
breezecomPrvRev OBJECT IDENTIFIER = 1.3.6.1.4.1.710.3
{breezecom 3}
brzPhoneMib OBJECT IDENTIFIER = 1.3.6.1.4.1.710.3.4
{breezecomPrvRev 4 }
Note: * is used instead of the phon prefix
Dialing Parameters
MIB Parameter
(Location in Parenthesis)
Description Values
*DialingParams
710.3.4.1
(brzPhonMib 1)
*PulseDialing
710.3.4.1.1
(*DialingParams 1)
Enables/disables automatic pulse
dialing detection.
Integer
disable (0)
enable (1)
na (255)
*GateKeeperOption
710.3.4.1.2
(*DialingParams 2)
Enables/disables communicating
with the Gatekeeper for call
management purposes.
Integer
disable (0)
enable (1)
na (255)
*GkGwIpAddress
710.3.4.1.3
(*DialingParams 3)
IP Address of the Gateway/
Gatekeeper
The parameters must be specified if
the [*GateKeeperOption] is enabled.
IP address
*MyTelephoneNumber
710.3.4.1.4
(*DialingParams 4)
The telephone number as specified
in the Gateway, if
[*GateKeeperOption] is disabled. If
the [*GateKeeperOption] is enabled
the number is transmitted to the
Gatekeeper.
DisplayString (SIZE (0..10))
Up to 10 characters.
0 means no number
*H323TerminalID
710.3.4.1.5
(*DialingParams 5)
The H323 Terminal ID (name) to be
used for calling the unit if the feature
is enabled.
Applicable only if the
[*GateKeeperOption] is enabled.
DisplayString (SIZE (0..25))
Up to 24 characters.
X=NoID
*IpDialingOption
710.3.4.1.8
(*DialingParams 8)
Enables/disables dialing using IP
addresses.
Integer
disable (0)
enable (1)
na (255)
*IpDialingIndicator
710.3.4.1.9
(*DialingParams 9)
Specifies the prefix used to identify
an IP dialing string.
DisplayString (SIZE (0..15))
Up to three telephone pad digits (0-9, A-D,
*, #).
X means no IP Dialing Indicator
*AutomaticPrefix
710.3.4.1.10
(*DialingParams 10)
Specifies a default prefix (number of
Gateway trunk) to be automatically
inserted before the dialed number.
DisplayString (SIZE (0..15))
Up to eight telephone pad digits (0-9, A-D,
*, #).
X means no Automatic Prefix.
*FastStart
710.3.4.1.13
(*DialingParams 13)
Enables/disables the fast connect
protocol.
Integer
disable (0)
enable (1)
na (255)