User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
Appendix C
C-31
BreezeACCESS Version 4.3 System Manual
AtpcTransmittedMessages
710.3.3. 8.6.2
(*AtpcCounters 2)
Applicable to IF based AU. The total
number of ATPC messages
transmitted by the unit since last
reset.
Integer
AtpcReceivedMessages
710.3.3. 8.6.3
(*AtpcCounters 3)
Applicable to SU units only. The
number of ATPC messages
received by the unit since
last reset regardless of whether the
unit supports ATPC.
Integer
*AUAlarms
710.3.3. 8.7
(*SiteSurvey 7)
Applicable to IF-based AU only. AU
Alarms parameters.
*AUAlarmsOption
710.3.3. 8.7.1
(*AUAlarms 1)
Applicable to IF-based AU only.
Disable/enable the AU Alarms test
mechanism.
Integer
disable (0)
enable (1)
*AUAlarmsLearningPeriod
710.3.3. 8.7.2
(*AUAlarms 2)
Applicable to IF-based AU only.
The time period after reset or after
enabling the AU Alarms Option that
is dedicated to accumulating
information only. During this period
the AU does not activate alarms,
except to the No Associations
alarm.
Integer
1 – 1440 (minutes)
*AUAlarmsTestCycle
710.3.3. 8.7.3
(*AUAlarms 3)
Applicable to IF-based AU only.
The tine interval between two
consecutive polling message
transmissions. This is also the time
interval used for calculating the
current averages for the various
traffic statistics.
Integer
1 – 1440 (minutes)
*AUAlarmsTrafficStatistics
710.3.3. 8.7.4
(*AUAlarms 4)
Applicable to IF-based AU only.
Traffic Statistics parameters.
*TrafficStatisticsTable
710.3.3. 8.7.4.1
(*AUAlarmsTrafficStatistics 1)
Applicable to IF-based AU only. Not
accessible. AU Alarms Traffic
Statistic Table containing traffic
statistics parameters and test
results.
*TrafficStatisticsEntry
710.3.3. 8.7.4.1.1
(*TrafficStatisticsTable 1)
Applicable to IF-based AU only. Not
accessible. An entry in the AU
Alarms Traffic Statistic Table.
*TrafficStatisticsType
710.3.3. 8.7.4.1.1.1
(*TrafficStatisticsEntry 1)
Applicable to IF-based AU only.
Read-only. The traffic statistics’
type of an entry in the AU Alarms
Traffic Statistics Table. Serves also
as the index of the entry.
Integer
retransmissionsRate (1)
droppedFramesRate (2)
crcErrorRate (3)
duplicateFramesRate (4)
*TrafficStatisticsCurrentRate
710.3.3. 8.7.4.1.1.2
(*TrafficStatisticsEntry 2)
Applicable to IF-based AU only.
Read-only. The current rate
calculated for the relevant statistics
type.
Integer
0 – 100 (%)
na (255)
*TrafficStatisticsAverageRate
710.3.3. 8.7.4.1.1.3
(*TrafficStatisticsEntry 3)
Applicable to IF-based AU only.
Read-only. The average rate
calculated since the last time the
unit was reset (or since the AU
Alarms Option was enabled) for the
relevant statistics type.
Integer
0 – 100 (%)
na (255)
*MinorAlarmMinimumDelta
710.3.3. 8.7.4.1.1.4
(*TrafficStatisticsEntry 4)
Applicable to IF-based AU only.
Read-write. The minimum
difference between the Traffic
Statistics Current Rate and the
Traffic Statistics Average Rate for
activating a minor severity alarm for
the relevant statistics type. Another
prerequisite for activating the alarm
is that the Traffic Statistics Current
Rate exceeds the Traffic Statistics
Minor Alarm Threshold.
Integer
0 – 100 (%)
MIB Parameter
(Location in Parenthesis)
Description Values/Range