User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
C-14
BreezeACCESS Version 4.3 System Manual
Manual Revision: 3.0
*HoppingBands (continued) BreezeACCESS 3.5b, 3.5ab:
frq3_5aGHzHoppingSequence10MHz (15)
frq3_5aGHzHoppingSequence12MHz (16)
frq3_5aGHzHoppingSequence14MHz (17)
frq3_5aGHzHoppingSequence24MHz (18)
frq3_5aGHzHoppingSequence28MHz (19)
frq3_5aGHzHoppingSequence36MHz (20)
frq3_5aGHzHoppingSequence42MHz (21)
frq3_5bGHzHoppingSequence50MHz (32)
frqFlexibleHopping (37)
frqSingleChannel3_5GHz (40)
frq3_5aGHzHoppingSequence24MhzPropriet
ary(69)
BreezeACCESS 3.8:
frq3_8GHzBand1 (0)
frq3_8GHzSelectable (1)
frq3_8GHzApprovalSpectrumMask (2)
frqFlexibleHopping (37)
frqSingleChannel3_8GHz (42)
BreezeACCESS 5.2: (read only)
frqFlexibleHopping (37)
BreezeACCESS 5.7
frg5_7GHzISMUsFCC(74)
frg5_7GHzInternational(75)
frg5_7GHzFlexibleHopping(37)
*MaxDataRate
710.3.3. 6.10
(*AirInterface 10)
Applicable to SU and AU. The
maximum transmission data rate.
Integer
max1Mbps (1)
max2Mbps (2)
max3Mbps (3)
na (255)
*TransmitPowerControl
710.3.3. 6.11
(*AirInterface 11)
Applicable to IF based units only.
Not applicable to AlvariBase,
AU-BS-WA Enables reducing the
transmit power level.
The maximum available value is for
maximum power. A lower value
reduces the transmitted power. The
resulting transmit power level
depends on the unit type (band) and
on the attenuation of the IF cable. In
SU, If ATPC is enabled the algorithm
uses it as the initial power level
.
Integer
BreezeACCESS II, XL and MMDS: 0-15
BreezeACCESS V: 0-7
na (255)
*RxAttenuationControl
710.3.3. 6.12
(*AirInterface 12)
Applicable to IF-based SU (SU-A/E)
only.
Enables to set the attenuation in the
receive path to 0, 10 or 25dB. The
effect of inserting such attenuation in
the receive circuit is equivalent to
reducing the level of the received
signal (including both signal and
noise) by 2dB when selecting 10dB
attenuation and 12dB when selecting
25dB attenuation.
Integer
low0dB (0)
med10dB (1)
high25dB (2)
na (255)
*MaximumVoiceSessions
710.3.3. 6.14
(*AirInterface 14)
Applicable to AU only.
The maximum number of
simultaneous voice sessions
permitted to guarantee minimum
quality.
Integer
0-50
na (255)
*FlexSubBandDef
710.3.3. 6.15
(*AirInterface 15)
Applicable to SU and AU only.
Flexible Hopping Definition
parameters.
MIB Parameter
(Location in Parenthesis)
Description Values/Range