User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
Menus and Parameters
2-101
BreezeACCESS Version 4.3 System Manual
Alarms Out Control
The Alarms Out Control menu allows the functionality of the Alarms Out
control mechanism to be defined. Its main purpose is to support
“manual” activation/deactivation of each of the Alarms Out either
locally or remotely using Telnet or SNMP. For each of the three Alarms
Out, the following control options are available:
0 – Turn Alarm OFF (even if it should be ON according to the
definition in the Automatic Alarms Out Definition Menu).
1 – Turn Alarm ON (even if it should be OFF according to the
definition in the Automatic Alarms Out Definition Menu).
2 – Automatic (activate/deactivate according to the definition in the
Automatic Alarms Out Definition Menu).
The default for all three Alarms Out is 2 (Automatic).
Show Alarm Parameters
Shows the current values of the Alarms In and Alarms Out parameters
as well as their current status:
Alarms In Names And Status
Displays the names and current status (ON or OFF) for all Alarm In
indications, including “internal” alarms, as follows:
Alarm In 1 through Alarm In 4: Name according to the name
defined in the Alarms In Names Menu.
Alarm In 5: GPS Antenna Status.
Alarm In 6: NA (reserved for future use).
Alarm In 7: PS1 Over Temperature (over temperature indication
for BS-PS Power Supply module 1, which is the module inserted
in the left-most slot of the chassis).
Alarm In 8: PS2 Over Temperature (over temperature indication
for BS-PS Power Supply module 2, which is the module inserted
in the right-most slot of the chassis).
Alarm In 9: PS1 Power (power fail indication for BS-PS Power
Supply module 1, which is the module inserted in the left-most
slot of the chassis).
Alarm In 10: PS2 Power (power fail indication for BS-PS Power
Supply module 2, which is the module inserted in the right-most
slot of the chassis).
Alarms Out Names, Definitions, Control and Status
Displays the following information for each of the three Alarms Out:
NOTE:
In some installations only one Power Supply module (either PS1 or PS2) may
be used.