User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
2-100
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 3.0
Show Alarm Parameters.
Alarms In Names
The Alarms In Names menu allows names for each of the four external
alarm indications that can be connected to the AL IN connector to be
defined. These names can reflect the specific environment in which the
module is being used (e.g. “Smoke Detector 1” or “Main Door”).
Each Alarms In Name can contain up to 31 printable ASCII characters
(case sensitive).
The default names are Alarm In 1 through Alarm In 4.
Alarms Out Names
The Alarms Out Names menu allows names for each of the three
external devices that can be connected to the AL OUT connector to be
defined. These names can reflect the specific environment in which the
module is being used (e.g. “Alarm Light 1”).
Each Alarms Out Name can contain up to 31 printable ASCII characters
(case sensitive).
The default names are Alarm Out 1 through Alarm Out 3.
Automatic Alarms Out Definition
The Automatic Alarms Out Definition menu allows you to define the
conditions under which each of the 3 Alarms Outs is to be activated
(when operating in Automatic mode). The available options for each of
the three Alarms Out are:
1 – Activate if Alarm In 1 turns ON.
2 – Activate if Alarm In 2 turns ON.
3 – Activate if Alarm In 3 turns ON.
4 – Activate if Alarm In 4 turns ON.
5 - Activate if Alarm In 5 (GPS Antenna Status) turns ON
6 - Not Applicable (Alarm In 6 is not defined)
7 - Activate if Alarm In 7 (PS1Over Temperature) turns ON
8 - Activate if Alarm In 8 (PS2 Over Temperature) turns ON
9 - Activate if Alarm In 9 (PS1 Power) turns ON
10 - Activate if Alarm In 10 (PS2 Power) turns ON
N – None (never activate this Alarm Out).
A - Activate if ANY of the Alarms In turns ON.
The default for all three Alarms Out is 0 (None – never activate the
alarm).