User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
Menus and Parameters
2-99
BreezeACCESS Version 4.3 System Manual
Automatic Recovery Mode - Enables to control an automatic
recovery process:
Automatic Recovery Option - To enable or disable
automatic initiation of antenna recovery process. If a GPS
antenna is not used, the Automatic Recovery Option should
be disabled.
The default selection is Enable.
Automatic Recovery Interval - To define the time interval
between two consecutive initiations of automatic antenna
recovery processes.
Valid values: 5 to 1440 (minutes)
Default value: 15 (minutes)
Alarm Parameters (GU)
The GU module serves also as the alarms control unit for the
BreezeACCESS system and auxiliary equipment. It has dry contact
connections to 4 external alarm inputs (Alarm In 1 through Alarm In 4),
that turn on upon contact closure. It also receives alarm indications
from BreezeACCESS power supply module (Alarm In 7 through Alarm
In 10), that turn on to indicate a power failure or over temperature
problem in any of the two optional power supplies. PS1 alarms refer to a
power supply module inserted in the left-most slot of the chassis. PS2
alarms refer to a power supply module inserted in the right-most slot of
the chassis. Alarm In 5 (GPS Antenna Status) is generated internally in
the GU module, and it is turned on to indicate that proper PPS (pulse
per second) timing signals are received from the GPS antenna.
The GU module can also control 3 Alarm Out relay, where each relay
has a common contact, a normally open (NO) contact and a normally
closed (NC) contact.
The Alarm Parameters menu allows access to the following sub-menus:
Alarms In Names.
Alarms Out Names.
Automatic Alarms Out Definition.
Alarms Out Control.
NOTE:
The GPS Antenna Recovery menu is applicable only to a "master" BS-GU module.
NOTES:
Over Temperature alarm indication is only supported by the AC power supply module.
In installations with a single power supply module, the GU module doesn’t function
(and therefore will not provide an alarm indication) upon total failure of the power
supply or upon failure of the 5 V module.