User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
2-84
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 3.0
The allowed range differs among codecs, in accordance with the
different packet sizes (30 ms for G723.1, 10 ms for G729 and 5 ms
for G711).
The valid values and default values are:
G723 Frames Per Packet – Valid range 1-8, Default value is 2
G729 Frames Per Packet – Valid range is 1-12, Default value is
6. If upgrading from a previous version, this value must be set to
6 if ACSE Option is enabled. (covers all G729 codecs, including
G729Annex A, G729wAnnexB and G729AnnexAwAnnexB)
G711u-law Frames Per Packet – Valid range is 1-16,
Default value is 12
G711A-law Frames Per Packet – Valid range is 1-16,
Default value is 12
Voice Activity Detection – Enables or disables the use of Voice
Activity Detection (VAD). When the VAD algorithm is enabled,
silence intervals are identified. Therefore, only relevant information
is transmitted, using less bandwidth than during voice activity
intervals. This allows for a better overall utilization of the available
bandwidth. Voice Activity Detection is not applicable when using the
G711 codec. Voice Activity Detection is implemented automatically
in G729wAnnexB and G729 Annex A w Annex B (Annex B activates
the silence compression).
Available options are:
Voice Activity Detection OFF.
Voice Activity Detection G7231 (enable when using G723.1
compression).
The default selection is Voice Activity Detection OFF.
Dialing Parameters (Subscriber
Units with Voice Support Only)
The parameters in the Dialing Parameters menu include the following
options:
Pulse Dialing – Enables or disables the automatic pulse dialing
detection feature to support telephones with pulse dialing.
The default selection is Enable.
Gatekeeper Option – If set to Enable, the unit will communicate
with the Gatekeeper to resolve the destination telephone number
NOTE:
When the ACSE Option is enabled, this parameter is not applicable and the default
value is always used.