User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
2-74
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 3.0
User Defined Addresses Only (only IP messages from/to IP
addresses included in the User Filter Addresses list pass).
PPPoE Protocol Only (only PPPoE frames pass - Ethernet
type 0x8863 and 0x8864).
The default selection is Disable.
Set User Filter Address – Displays the current User Filter IP
addresses. Allows you to enter up to 8 IP addresses to be used if
the User Defined Addresses Only option was selected in the User
Filtering Option above.
The default for all addresses is 0.0.0.0.
Set User Filter Mask – Displays the current masks. Allows you
to enter subnet masks for each of the User Filter IP Address
entries.
The default for all subnet masks is 255.0.0.0.
Set User Filter Range – Defines a range of addresses for each of
the User Filter IP Address entries (the range includes the base
address).
Valid values: 0 – 255.
The default value is 0 (not used).
Delete a User Filtering Entry – Displays the current list of IP
addresses, subnet masks and ranges. Enter the list number
(from 0 to 7) to delete the entry from the list (the list number will
be replaced by the default values).
Delete All User Filtering Entries – Deletes all User Filtering
entries (and replaces them with the default values).
Show All User Filtering Parameters – Displays the current
User Filtering Option and the list of User Filtering addresses,
subnet masks and ranges.
MIR and CIR Parameters – The CIR (Committed Information Rate)
value specifies the minimum data rate guaranteed to the applicable
subscriber. The MIR (Maximum Information Rate) value specifies
the maximum data rate available for burst transmissions, provided
such bandwidth is available.
Under normal conditions, the actual Information Rate (IR) will be
between the applicable CIR and MIR values: IR=CIR+K(MIR-CIR),
where K is between 0 to 1 and is determined dynamically by the AU
according to overall demand in the cell and the prevailing conditions
NOTES:
You may use either Mask or Range (but not both) to define a group of user filter
addresses.
If IP broadcast packets should reach the devices connected behind the SU unit,
the Broadcast IP address should be included in the configured User Filter
Address entries.