User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
2-72
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 3.0
Dwell Time (AU only) – The time spent on a radio channel before
hopping to the next channel according to the operational hopping
sequence.
The allowed selections are 32, 64 and 128 Kilo-microseconds.
The default value is 128 Kilo-microseconds.
When the ACSE Option is enabled this parameter is not applicable
and the dwell time is the ACSE Dwell Time, set to a fixed value of 60
milliseconds.
Interference Avoidance Parameters: These parameters enable to
define the interference avoidance algorithm. The algorithm is
designed to minimize the probability of the modem identifying
interference as a possible desired signal. Such an occurrence should
be avoided, as locking on the interfering signal may disable the
modem from timely identifying the appearance of a desired signal.
Setting a certain level as a threshold below which signal are
considered as interference is not sufficient, since the energy in the
relevant spectrum of interfering signals may temporarily be well
above the threshold level. On the other hand, setting the threshold
at a higher level to overcome the effect of temporary occurrences of
high-level interferences is not a good solution, as it may cause the
unit to reject desired signals. The solution is a dynamic decision
algorithm that will follow temporary high-level interferences and
adjust the decision threshold accordingly.
There are two different algorithms; one for identifying transmissions
of messages initiated by another unit, and one for identifying
response from another unit to a message transmitted by the unit.
The algorithm for identifying transmissions of messages initiated by
another unit includes two settable parameters: Noise Floor and
Carrier to Interference Difference Level.
The Noise Floor parameter represents the equivalent noise level in
the neighborhood of the unit, including both the thermal noise and
average level of interference in the relevant spectrum.
Carrier to Interference Difference Level is the minimal difference
between the level that is defined as the Current Noise Level and the
level of a “good” signal (a signal that the unit should treat as a
possibly desired signal).
The modem of the unit continuously estimates the level of the
received energy at the relevant spectrum. The Current Noise Floor
is defined as follows:
If the last estimated energy level was lower than or equal to the
Noise Floor, then the Current Noise Floor is equal to the Noise
Floor.
If the last estimated level was above the Noise Floor, it can be either
interference or a possibly “good” signal. If it is lower than the last
Current Noise Floor, or if the difference from the last Current
Noise Floor is less than the Carrier to Interference Difference