User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
2-34
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 3.0
The default parameters for these alarms is as follows:
Show Traffic Statistics Parameters and Data - Displays for each
statistics type the configured parameters as well as the
applicable Current and Average Rates.
SU Rx Power Test - A sub menu that includes the following
options:
SU Rx Power Decrease Threshold - The minimum inverse
(negative) value of the SU Rx Power Average Delta that will
trigger an alarm.
Valid values: 1 to 99 (dBm).
Default value: 15 (dBm).
Show SU Rx Power Test Parameters and Data - Displays the
value of the SU Rx Power Decrease Threshold and the current
SU Rx Power Average Delta.
AU Rx Power Test - A sub menu that includes the following
options:
AU Rx Power Decrease Threshold- The minimum inverse
(negative) value of the AU Rx Power Average Delta that will
trigger an alarm.
Valid values: 1 to 99 (dBm).
Parameter Default (%)
Retransmission Minor Alarm Minimum Delta 20
Retransmission Minor Alarm Threshold 30
Retransmission Major Alarm Threshold 60
Dropped Frames Minor Alarm Minimum Delta 10
Dropped Frames Minor Alarm Threshold 10
Dropped Frames Major Alarm Threshold 20
CRC Error Minor Alarm Minimum Delta 20
CRC Error Minor Alarm Threshold 40
CRC Error Major Alarm Threshold 70
Duplicate Frames Minor Alarm Minimum Delta 5
Duplicate Frames Minor Alarm Threshold 5
Duplicate Frames Major Alarm Threshold 15
NOTE:
The value of the Major Alarm Threshold must be higher than the applicable
Minor Alarm Threshold. The system will not accept a Major Alarm Threshold
that is lower than the current Minor Alarm Threshold, and vice versa.