User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
Menus and Parameters
2-33
BreezeACCESS Version 4.3 System Manual
The AU Alarms Menu
The AU Alarms menu enables to configure relevant parameters and to
view current statistics. The AU Alarms menu is available only with
Administrator access rights, except for Show All AU Alarms
Parameters and Data that is also available with Installer access rights.
AU Alarms Option - Enables to enable or disable the AU Alarms
feature. The default is Disable.
Learning Period - Enables to define the period dedicated to
accumulating information without generating alarms (except for the
No association alarm).
Valid values: 1 to 1440 (minutes)
Default: 30 (minutes)
Test Cycle - Enables to define the time between two consecutive
transmissions of a polling message and for calculating the current
averages for the various traffic statistics.
Valid values: 1 to 1440 (minutes)
Default: 10 (minutes)
Traffic Statistics - A sub menu that includes the following options:
Retransmissions Rate Parameters
Dropped Frames Rate Parameters
CRC Error Rate Parameters
Duplicate Frames Rate Parameters
For each of these traffic statistics types, a sub menu enables to
configure three parameters:
Minor Alarm Minimum Delta - The minimum difference
between the Current Rate and the previous Average Rate,
for activating a minor severity alarm, for the relevant
statistics type. Another prerequisite for activating the alarm
is that the relevant Current Rate exceeds the applicable
Minor Alarm Threshold.
Valid range: 0 to 100 (%)
Minor Alarm Threshold - The threshold for activating a
minor severity alarm for the relevant traffic statistics type.
Another prerequisite for activating the alarm is that the
difference between the applicable Current Rate and the
previous Average Rate exceeds the Minor Alarm Minimum
Delta.
Valid range: 1 to 100 (%)
Major Alarm Threshold - The threshold for activating a
major severity alarm for the relevant statistics type.
Valid range: 1 to 100 (%)