User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
Menus and Parameters
2-19
BreezeACCESS Version 4.3 System Manual
The Rx, Tx and RTx per hop counters accumulate the number of
applicable frames since last reset. The counters can also be reset using
the Reset Counters option in either the Per Hop Statistics menu or in
the Traffic Counters menu.
The general rate (Frames per second) statistics is the average rate
during the last 64 hops.
The display is continuously updated. Press any key to exit.
Ping Test (AU, SU and GU)
The Ping Test menu includes the following options:
Destination IP Address – Displays the IP address of the destination
unit for pinging. Allows entering an IP address (4 x 3 digit octets,
separated by dots).
The default IP address is 192.000.000.001.
No. of Pings – Enter the number of ping attempts per session.
The allowed range is from 0 to 9999. Select 0 for continuous
pinging.
The default value is 1.
Ping Frame Length – Enter the ping packet size.
The allowed range is from 60 to 1472 bytes.
The default value is 64 bytes.
Ping Frame Timeout – Enter the ping frame timeout, which is the
amount of time (in ms) to wait between ping attempts.
The allowed range is from 200 to 60000 ms, in increments of 200
milliseconds (200, 400, 600,……60000).
The default value is 200 ms.
Hopping Statistics
Num The number of the information row, assigned automatically and
sequentially by the program.
Freq The hopping frequency, according to the hopping sequence.
Rx The accumulated number of frames received at the specified frequency
since last reset.
Tx The accumulated number of frames transmitted successfully at the
specified frequency since last reset.
RTx The accumulated number of frames re-transmitted at the specified
frequency since last reset.
avrDBM
(avrRSSI)
The average RSSI (Received Signal Strength Indication) in dBm or
RSSI units (according to the RSSI Display Option) of all the frames
received at the specified frequency since the last reset. If no frames have
been received, the avrRSSI is NA (Not Available).