User's Manual
Table Of Contents
- BreezeACCESS Version 4.3 System Manual Revision 3.0
- Contents
- Book 1: System Description
- Contents
- Chapter 1 - Introduction
- Chapter 2 - System Components
- Chapter 3 - Specifications
- System Specifications
- BreezeACCESS II Radio Regulatory Standards
- Data Communication
- Voice/Fax (Subscriber Units with voice support)
- Telephony (Subscriber Units with voice support)
- IF Indoor – Outdoor Communication
- (SU-A/E, AU-A/E-NI, AU-A/E-BS)
- Configuration and Management
- GU-RA GPS Radio
- GU-RA to BS-GU Communication
- Environmental
- Standards Compliance, General
- Physical Specifications
- System Specifications
- Book 2: Installation
- Contents
- Chapter 1 - IF-Based Equipment
- Packing Lists
- SU-A/E Subscriber Unit
- Modular Base Station Equipment
- Standalone AU-A/ENI Access Unit
- Other Items Required for Installation
- Guidelines for Selection of Equipment Locations
- Installing the Outdoor Unit
- Installing the SU-NI and AU-NI Indoor Unit
- Installing Modular Base Station Equipment
- Installing the GU-A-BS GPS and Alarms System
- Chapter 2 - Indoor SU-R Units
- Chapter 3 - Indoor SU-I and AU-I Units
- Book 3: Commissioning
- Book 4: Operations and Administration
- Contents
- Chapter 1 - Accessing the Monitor Program
- Chapter 2 - Menus and Parameters
- Main Menu
- Info Screens Menu
- Unit Control Menu
- Basic Configuration Menu
- Site Survey Menu
- Traffic Statistics (AU and SU)
- Voice Statistics (SU with Voice Support Only)
- Per Hop Statistics (AU and SU)
- Ping Test (AU, SU and GU)
- Continuous Link Quality Display (Available in SU Only)
- MAC Address Database (Available in AU Only)
- Per-rate Counters (AU and SU)
- RSSI Display Option (AU and SU)
- ATPC Counter (AU and SU)
- AU Alarms (IF-based AU Only)
- Advanced Configuration Menu
- IP Parameters (AU, SU and GU)
- Air Interface Parameters (AU and SU)
- Network Management Parameters (AU, SU and GU)
- Bridge Parameters (AU, SU and GU)
- Performance Parameters (AU and SU)
- Service Parameters (AU and SU)
- RADIUS Parameters Menu (Subscriber Units only)
- Security Parameters (AU and SU)
- Voice Parameters (Subscriber Units with Voice Support Only)
- Dialing Parameters (Subscriber Units with Voice Support Only)
- Telephony Signals (Subscriber Units with Voice Support Only)
- Hopping Parameters (GU)
- Alarm Parameters (GU)
- Appendices
- Appendix A - Configuration Download/Upload
- Appendix B: Software Version Loading Procedure
- Appendix C: Supported MIBs and Traps
- BreezeACCESS System Object Identifiers
- brzAccessMIB
- Service Parameters
- RADIUS General Parameters
- Accounting Parameters
- RADIUS Authentication Parameters
- User Filtering Parameters
- Network Management Parameters
- Bridge Parameters
- Air Interface Parameters
- Performance Parameters
- Site Survey Parameters
- Special Operations Parameters
- Unit Control Parameters
- IP Parameters
- System Information Parameters
- Alarms Parameters
- brzPhoneMIB (applicable to SU with voice only)
- Supported Traps
- Appendix D: RSSI to dBm Conversion Table
- Appendix E: Parameters List
- Appendix F: Hopping Sequences
- Index
2-10
BreezeACCESS Version 4.3 Operations and Administration
Manual Revision: 3.0
Change Password – Changes the password(s). A user with Installer
access rights can change the passwords for Read Only and Installer
levels. A user with Administrator access rights can change the
passwords of all levels.
Valid values: A string of up to 8 printable ASCII characters.
Table 1-1‚ page 1-2 lists the default passwords for each of the access
levels.
Flash Memory Control – Selects the active software version. The
following options are available:
Reset and Boot from Shadow Version – Activates the Shadow
(backup) software version. The unit resets automatically and
loads the shadow firmware.
Use Current Version After Reset – Defines the current version
as the one that will be activated and used after the next reset.
The flash memory can store two software versions. One version is
called Current and the other is called Shadow. New software
versions are loaded as the Shadow version. You can select the
Shadow version as the new active version by selecting Reset and
Boot from Shadow Version. However, after the next reset, the
Current version will be activated again. If you wish to continue
using the currently active version after the next reset, select Use
Current Version After Reset.
The parameters configured in the unit are not changed as a result of
downloading new software versions (unless the new version includes
additional parameters or other changes in the list of parameters).
New parameters are loaded with their default values.
Console Speed – Defines the speed at which the unit communicates
with the terminal running the terminal emulation program. This
parameter must be changed prior to changing the speed of the
terminal connected to it.
The allowed speeds are: 9600, 19200, 38400, 57600 and 115200
baud.
The default value is 9600 baud.
Log Out Timer – Enters a new Log Out Timer value. If the monitor
program is not used for the specified time, the unit will
automatically exit the monitor program.
The allowed range is 1 to 999 minutes.
The default value is 5 minutes.
Event Log Menu – Controls the event log feature. The event log is
an important debugging tool and a flash memory sector is dedicated
NOTE:
The Passwords are not changed upon setting the unit to default values (either Partial
or Complete).