User's Manual

Table Of Contents
Setting Basic Parameters
1-5
BreezeACCESS Version 4.3 System Manual
Configuring Basic Parameters
in Access and Subscriber
Units
The Basic Configuration menu in the Monitor program includes all the
parameters necessary for the initial operation of BreezeACCESS
Subscriber and Access Units. In many installations, most of these
parameters should not be changed from their default values. The
following list includes the basic parameters and their default values:
Table 1-3: Subscriber and Access Units Basic Parameters
Parameter Default Value Comment
IP Address 10.0.0.1
Subnet Mask 255.0.0.0
Default Gateway Address 0.0.0.0
DHCP Option Disable
Access to DHCP AU: From Ethernet Only
SU: From Wlan Only
Hopping Set (AU) 1
Hopping Sequence (AU) 1
Hopping Sync
(AU-BS only)
Idle 1. Cannot be changed in units
configured to country standard
US FCC, Canada and Australia.
2. If synchronization without
GPS is to be supported, one AU
should be configured to Master,
all other AUs should be
configured to Slave.
3. When GPS is used for
synchronization, all AUs should
be configured to Slave.
Transmit Antenna
(SU-R, SU-I/AU-I)
Antenna 1
Transmit Power Control
(IF-based units)
15
Power Level
(SU-R, SU-I/AU-I with HW
revision C or lower)
High Cannot be changed in units
configured in the factory to
“Low” for compliance with local
regulations.
Transmit Level (SU-I/AU-I
with HW revision D or higher)
17
ATPC Option
(IF-based units)
AU Disable
SU: Enable