User's Manual

Table Of Contents
Chapter 4 - Operation Radio Parameters
BreezeMAX PRO 5000 CPE 68 Product Manual
Start Rx Frequency (KHz): the lowest frequency in the range of frequencies to
be scanned (in KHz).
The available values depend on the radio band of the unit.
End Rx Frequency (KHz): the highest frequency in the range of frequencies to
be scanned (in KHz).
The available values depend on the radio band of the unit.
Scanning Main Step (MHz): the Main Scanning Step that together with the
Intermediate Scanning Steps define the frequencies to be scanned between the
Start and End Rx Frequencies.
The main steps can be 2.5 MHz or 5 MHz. The default is 2.5 MHz.
Scanning Intermediate Steps (KHz): the Intermediate Scanning Steps that
together with the Main Scanning Step define the frequencies to be scanned
between the Start and End Rx Frequencies.
The Intermediate Scanning Steps include 8 Steps that define the intermediate
scanning steps as described above. The default is Enable for the B0 Start
Frequency Scan.
Bandwidth: enables to select either a specific bandwidth (according to the
options supported by the unit) or scan all supported bandwidths (Auto).
The default is Auto mode.
To change the bandwidth, select the required bandwidth from the list and click
Apply. A reset required message is displayed. Click OK to reset the unit, or
Cancel to cancel the operation.
Discrete Frequencies: enables editing the list of discrete frequencies that will
be included in the Frequency Scanning Table. If no discrete frequency has
been added, N/A will be displayed. To delete a discrete frequency from the list,
NOTE
In the current version, intermediate steps are disabled.