User's Manual
Table Of Contents
- BreezeMAX PRO 5000 CPE
- About This Manual
- Contents
- Figures
- Tables
- Products Description
- Installation
- Commissioning
- Operation
- 4.1 Introduction to SU Management
- 4.2 Accessing the Web Configuration Server
- 4.3 Using the Web Configuration Server
- 4.4 Show All
- 4.5 Unit Control Parameters
- 4.6 Registration Parameters
- 4.7 BST/AU Parameters
- 4.8 Radio Parameters
- 4.9 ATPC Parameters
- 4.10 Performance Monitor
- 4.11 Service Parameters
- 4.12 Management Parameters
- 4.13 Logout
- 4.14 Parameters Summary
- Troubleshooting
- Glossary
Chapter 3 - Commissioning Configuring Basic Parameters
BreezeMAX PRO 5000 CPE 33 Product Manual
3.2.2 Configuration Tools
The SUs include a Web Configuration Server, providing a web-based GUI for local
configuration and monitoring. The Web Configuration Server can be accessed
using a PC/Notebook with a web browser.
The SU may be delivered with the operator’s default settings already configured in
the FLASH memory. If there is need to change these settings then the only
parameters that should be configured are the end user’s credentials (User Name
and User Password).
3.2.3 Using the Web Configuration Server
1 Connect a PC/Notebook with a web browser to the Ethernet port of the SU,
using a straight Ethernet cable.
2 Configure the PC's IP parameters to enable connectivity with the unit. The IP
address of the SU for local management access is 192.168.254.251. The
Subnet Mask is 255.255.255.0. The recommended IP address for the PC is
192.168.254.250, as this is also the default TFTP Sever IP Address (required
for downloading SW versions and for downloading/uploading configuration
files).
3 Open a web browser, and connect to http://192.168.254.251. The “Enter the
Password” prompt is displayed. Enter the password and press the Enter key.
To configure the SU's basic parameters:
NOTE
The default password is "installer".
Figure 3-1: Login Window