Chapter 4 - Operation Management Parameters
BreezeMAX PRO 5000 CPE 82 Product Manual
4.12 Management Parameters
The Management Page enables viewing the parameters related to remote (over the
air) management of the device, and configure the parameters of the DHCP client.
The Management Parameters menu includes the following options:
Management Parameters
DHCP Client Configuration
4.12.1 Management Parameters
The Management page enables viewing the parameters related to remote (over the
air) management of the device and to set the DSCP classifier.
The following parameters are displayed:
Factory Defaults DSCP Classifier
Actual Used DSCP Classifier: the DSCP classifier used when the CPE is
connected. When the CPE is not connected, the value is N/A.
Configured DSCP (to change, enter a value and click Apply). Range 0-63;
Default 6
Management IP Address (acquired from a DHCP server during Network Entry)
Figure 4-20: Management Page