Chapter 4 - Operation BST/AU Parameters
BreezeMAX PRO 5000 CPE 65 Product Manual
» Configured Best BS ID: the configured Preferred BST/AU ID. Together with
the BS ID Mask, it is used to define the range of BSs that can communicate
with the unit.
The BS ID comprises 6 octets of up to 3 digits each, where the range of
each group is 0 to 255.
The default BS ID is 0.0.0.0.0.0
» Current Best BS ID
» Selected Best BS ID
» Preferred Best BS ID
» Current Preferred BS ID
If a BS ID is set on the preferred BS and the mask is
255.255.255.255.255.255 and the CPE finds it in the discrete frequency
list or in the full range, it will immediately connect to it.
Selected BST/AU Parameters:
» Selected BST/AU ID: The BST/AU ID to which the CPE is currently
connected.
» Selected Rx Frequency: The Rx Frequency of the BTS to which the CPE is
currently connected.
» Selected Best BS RSSI: The Rx RSSI of the BTS to which the CPE is
currently connected.
» Selected Best BS SNR (dB): The Rx SNR of the BTS to which the CPE is
currently connected.
» Selected BW: The bandwidth of the BTS to which the CPE is currently
connected.
Best BST/AU Table: displays the following details for each of the BS(s) found
during the scanning process:
» BS ID