User's Manual

Table Of Contents
Chapter 2 - Installation Installing the ODU of the CPE
BreezeMAX PRO 5000 CPE 22 Product Manual
2 Insert the cable with the assembled connector through the sealing nut.
3 To expose the groove, lightly squeeze the seal. Carefully insert the cable
through the groove.
4 Insert the cable through the housing and insert the seal at the back end of the
housing.
5 Tighten the sealing nut onto the housing.
6 Stricken the gasket on the front end of the housing.
7 Connect the Ethernet cable to the IDU COM RJ-45 connector and tighten the
sealing cap.
8 Route the cable to the location selected for the indoor equipment.
9 Assemble an RJ-45 connector with a protective cover on the indoor end of the
IDU-ODU cable. Refer to the pin assignment and color codes in standard
cables described above.
2.1.6.3 Connecting the Antenna Cable (units with external antenna)
1 Mount the antenna as close as possible to the ODU.
2 Connect one end of the coaxial RF cable to the RF connector (marked )
located at the top panel of the unit (see Figure 2-5).
3 Connect the other end of the RF cable to the antenna.
4 The RF connectors should be properly sealed to protect against rain and
moisture.
Figure 2-7: Inserting the IDU COM Cable into the Sealing Cap
To connect the RF cable:
Seal
Housing GasketSealing nut