User Manual

Table Of Contents
Chapter 2 - Installation Installing the IDU-1D Indoor Unit of the PRO 5000 CPE
BreezeMAX PRO 5000 CPE 25 Product Manual
* After power-up, the WIRELESS LED illuminates until self-test is finished.
2.2.3.1.1 RESET Button
The recessed RESET button is located on the front panel of the unit. When
pressed, power to the ODU is disconnected (hard reset).
RADIO
(on the front panel)
10/100Base-T (RJ-45) Connection to the ODU
POWER
(on the bottom panel)
3-pin AC Mains power connection
Table 2-5: CPE-IDU-1D LEDs
Name Description Functionality
POWER (3) Power Indication
Off - IDU is not powered or power failed
Green - IDU power is OK
ETH (2) Ethernet link status
(Ethernet integrity)
Off - No Ethernet connectivity has been detected between
the outdoor unit and the device connected to the indoor
unit’s data port
Green - Ethernet connectivity has been detected between
the outdoor unit and the device connected to the indoor
unit’s data port
WIRELESS (1) Wireless link status
Off - SU is not associated with a BS
Green - SU is connected with a BS (network entry
completed)
Blinking Green - Authentication failed
Table 2-4: CPE-IDU-1D Connectors
Name Connector Functionality