Chapter 2 - Installation Installing the ODU of the PRO CPE
BreezeMAX PRO 5000 CPE 21 Product Manual
Data pairs are 1&2, 3&6.
Power pair (proprietary solution) is 4&5.
The color codes used in standard cables supplied by Alvarion are as listed in the
following table:
1 The seal has a special groove allowing to insert an ethernet cable with an
already assembled RJ-45 connector. Strip the cable sheath and crimp the
RJ-45 plug.
2 Insert the cable with the assembled connector through the sealing nut.
3 To expose the groove, lightly squeeze the seal. Carefully insert the cable
through the groove.
4 Insert the cable through the housing and insert the seal at the back end of the
housing.
5 Tighten the sealing nut onto the housing.
6 Stricken the gasket on the front end of the housing.
Table 2-3: Cable Color Codes
Wire color Pin
Blue 1
Blue/white 2
Orange 3
Orange/white 6
Brown 4
Brown/white 5
Green 7
Green/white 8
To connect the IDU-ODU cable: